loading

Wenzhou Suote - Professional Pharmaceutical, Chemical And beverage Processing Equipment Manufacturer Since 1998.

SS30408 Stainless Steel 1000L Storage Tank E6201(6016-E2201) with 316L Internal Coil

×
SS30408 Stainless Steel 1000L Storage Tank E6201(6016-E2201) with 316L Internal Coil

Design & Compliance

  • Standards Adherence:
    • GMP (2022 Revised Edition) Articles 31–32 for pharmaceutical production.
    • GB150–98 (Steel Pressure Vessels) and JB/T4735–97 (Steel Welded Atmospheric Vessels).
  • Material Specifications:
    • Shell: SS30408 stainless steel (equivalent to 304).
    • Internal coil: 316L stainless steel for corrosion resistance.
    • Polishing: Inner surface mirror-finished to Ra≤0.28μm; outer surface options: polished, mirrored, sandblasted, or cold-rolled matte.

Structural Features

  1. Hygienic Connections:
    • ISO quick-fit clamp connections for easy disassembly and cleaning.
  2. Functional Nozzles:
    • Inlet/outlet, reflux port, disinfection port, CIP cleaning port.
    • 0.22μm air breather and sanitary manhole for sterile operation.
  3. Capacity Range:
    • Standard sizes: 20L to 10,000L; custom designs available per requirements.
  4. GMP Documentation:
    • Includes material certificates, component 合格证 (compliance certificates), and validation records.

Technical Advantages

Feature Benefit
Hermetic Sealing Prevents external contamination and insect intrusion.
Pressure Resistance Suitable for high-pressure applications (up to 0.3MPa working pressure).
316L Internal Coil Resists corrosion from aggressive media (acids, alkalis, salts).
CIP/SIP Compatibility Enables in-situ cleaning and sterilization for hygienic processes.

Applications

  • Food & Beverage: Wine brewing, dairy storage, juice concentration.
  • Pharmaceuticals: API storage, parenteral solution holding, buffer preparation.
  • Cosmetics: Emulsion storage, fragrance blending.
  • Chemical: Solvent storage, intermediate product containment.

Installation & Maintenance

  • Installation:
    • Ensure vertical alignment; level the tank before use.
    • Connect CIP/SIP systems to designated ports for routine sanitization.
  • Maintenance Tips:
    • Regularly inspect gasket integrity (replace every 6–12 months).
    • Perform pressure testing (1.25x design pressure) annually for safety.

prev
The Allure of MT Magnetic Stirrers: Seamless Mixing for Demanding Industries
Installation and Operation of Magnetic Stirring Reactors
next
recommended for you
no data
GET IN TOUCH WITH Us
Ready to work with us ?
Copyright © 2025 Wenzhou suote pharmaceutical and chemical engineering CO.,LTD  | Sitemap Privacy Policy
Contact us
whatsapp
Contact customer service
Contact us
whatsapp
cancel
Customer service
detect